The Belfort Ultrasonic WxPak weather station meets a growing need for real time, site-specific weather information. The unit provides accurate data when monitoring weather conditions on-site or in remote locations.
The WxPak Weather Station is the only all in-one weather station that calculates apparent wind speed and direction, barometric pressure, air temperature, relative humidity, dew point and wind chill temperature. With the internal compass and GPS, true wind speed and direction can also be calculated. The UV stabilized, compact housing is fully waterproof and resistant to chemicals lightning strikes.
| Wind Speed Range |
0 m/s to 40 m/s (0 MPH to 92 MPH) |
| Wind Speed Resolution |
0.1 m/s (0.1 MPH) |
Wing Speed Accuracy @
0°C to 55°C (320F to 131°F), no precipitation* |
Low Wind Speeds:
0 m/s to 5 m/s (0 MPH to 11.5 MPH):
RMS error of 0.5 m/s (1.1 MPH) + 10% of reading
High Wind Speeds:
5 m/s to 40 m/s (11.5 MPH to 92 MPH):
RMS error of 1 m/s (2.3 MPH) or 5% RMS,
whichever is greater |
Wind Speed Accuracy
in wet conditions** |
2.5 m/s (5.7 MPH) RMS |
| Wind Direction Range |
0° to 360° |
| Wind Direction Resolution |
0.1° |
| Wind Direction Accuracy @ 0°C to 55°C (32°F to 131°F), no precipitation* |
Low Wind Speeds:
2 m/s to 5 m/s (4.6 MPH to 11.5 MPH) – 50 RMS typica
High Wind Speeds:
>5 m/s (>11.5 MPH) – 20 RMS typical |
Wind Direction Accuracy
in wet conditions** |
>4 m/s (9.2 MPH) – 80 RMS typical |
| Compass Accuracy |
1° RMS when Level |
| Pitch and Roll Range/Accuracy |
±50° / <1° static tested @ 25°C (77°F) |
| Air Temperature Range |
-25° to 55°C (-13°F to 131°F) |
| Air Temperature Resolution |
0.1°C (0.1°F) |
| Air Temperature Accuracy |
±1°C (+1.8°F)* @ >4 knots (>4.6 MPH) wind |
| Barometric Pressure Range |
300 mbar to 1100 mbar
(8.86 inHg to 32.48 inHg, 300 hPa to 1100 hPa) |
| Barometric Pressure Resolution |
0.1 mbar (0.029 inHg. 0.1 hPA) |
| Barometric Pressure Accuracy |
±2 mbar (±0.059 inHg. ±2 hPa)
when altitude correction is available |
| Relative Humidity Range |
10% to 95% RH |
| Relative Humidity Accuracy* |
±4% units RH |
| GPS Position Accuracy |
3 m (10’) with WAAS/EGNOS
(95% of the time, SA off) |
| Operating Temperature Range |
-25°C to 55°C (-13°F to 131°F) |
| Supply Voltage |
9 VDC to 16 VDC |
| Supply Current |
<150 mA |
| Weight |
258 grams (0.7 lb) |
| Sensor Baud Rate (RS422 with NMEA 0183 Interface Only) |
4,800 BPS (Can be increased to 38,400 bps with command) |
| Thread Sizes on Base |
1-14” UNS or
3/4” NPT |
| Certifications and Standards |
CE, RoHS |